Jobedly Post a Job

Data Center Generator Service Technician

Amazon · Manassas, VA
Full-timeTechnologyEntry Level$32–$57/yr
Apply on Jobedly ⚡ One-click AI Apply

About the Data Center Generator Service Technician role

Data Center Generator Service Technician positions focus on delivering results in their domain. This page aggregates open Data Center Generator Service Technician roles and what employers typically expect.

AWS Infrastructure Services (AIS) owns the design, planning, delivery, and operation of all AWS global infrastructure. In other words, we’re the people who keep the cloud running. We support all AWS data centers and all of the servers, storage, networking, power, and cooling equipment that ensure our customers have continual access to the innovation they rely on. We work on the most challenging problems, with thousands of variables impacting the supply chain — and we’re looking for talented people who want to help. You’ll join a diverse team of software, hardware, and network engineers, supply chain specialists, security experts, operations managers, and other vital roles. You’ll collaborate with people across AWS to help us deliver the highest standards for safety and security while providing seemingly infinite capacity at the lowest possible cost for our customers. And you’ll experience an inclusive culture that welcomes bold ideas and empowers you to own them to completion. The Generator Service Technician has safety, customer satisfaction, and business responsibilities within data center operations. The person in this role is responsible for identifying, troubleshooting, diagnosing and providing quality repairs of electrical generator systems and related engine mechanical failures. The Generator Service Technician is both the technical expert and primary customer support contact to the customer, and is therefore responsible for continually communicating with the customer to provide an exceptional customer experience and drive data center up-time and availability. Key job responsibilities Daily building rounds to monitor and record information from electrical, mechanical, and fire/life safety equipment to ensure 24/7 reliability and availability Monitor Building Management Systems (BMS) and Electrical Power Management System (EPMS) Assist in troubleshooting of facility and rack-level events within internal Service Level Agreements (SLA) Perform rack installs and rack decommissioning within internal SLA Perform PM, troubleshooting, root cause analysis, and repair of electrical and mechanical equipment Technical writing to support change management program Monitor daily work requests and manage to resolution, and execute projects from conception to completion On-site support of contractors, sub-contractors and vendors, ensuring that all work performed is in accordance with established practices, procedures & local legislation Work schedule changes depending on specific site needs. Shifts can be up to 12 hours and may rotate on a predefined schedule. Some locations have on-call rotations. Role may support more than one location/site. Physical Requirements: Willingness and demonstrated ability to work in the following physical conditions with reasonable accommodations: Regularly lift and/or move up to 39 pounds independently Participate in group lifts for 40+ pounds Maintain balance and perform construction tasks while on a ladder Regularly walk, use hands and fingers, handle or feel, reach with hands and arms, stoop, kneel, crouch or crawl, climb stairs, twist, bend, work above shoulders, grasp, carry, push and pull objects into position Work in an environment requiring provided ear protection This role supports data centers in various operational stages. The position may be assigned to a facility still under development, which could require travel to established locations for training until your designated site becomes fully operational. Essential Requirements: Ability to travel to or commute between data center locations as needed Willingness to temporarily work at alternative sites during training periods or until assigned facility is operational Travel frequency will vary based on business needs and operational status of assigned facility Candidates must be able to travel (over 50 miles) or commute (less than 50 miles) to active data center sites as required by business needs. ## Basic qualifications - 1+ years of electri…

Salary estimate

$32 – $57/yr
Provided by the employer.

Skills for this role

AWSSecurity

Resume tips for Data Center Generator Service Technician applicants

Interview preparation

Prepare concrete STAR-format stories that show Data Center Generator Service Technician outcomes you drove.

Research the employer's product and recent news before the interview.

Be ready to explain how you'd approach a typical Data Center Generator Service Technician problem end to end.

Have thoughtful questions ready about the team, tools and success metrics.

About Amazon

Amazon is actively hiring on Jobedly. Explore their open roles and what it's like to work there.

Apply on Jobedly ⚡ One-click AI Apply

Similar jobs

Companies hiring for similar roles